DSCB
Load-resistance digital load cell
Product outline
Not only the characteristics of a high stiffness load cell, but noise resistant digital output incorporated!
● Capacity 1 kN / 2 kN / 5 kN / 10 kN / 20 kN / 50 kN
● High stiffness and Safe overload of 500%
● Excellent maintainability
● Amplifier incorporated
● Hold function and high/low limit comparison function can be used without an indicator!
● Displays load change on PC in real-time
High stiffness and Safe overload of 500%
As deformation under load is small, DSCB can be used safely for measuring cutting
or
grinding force.
With its 500% safe overload, DSCB can stably measure even severe load over a
long
period.
Excellent maintainability
It is unnecessary to reset the zero point and the sensitivity for the indicator
and
troublesome cable laying according to a replacement of DSCB.
Customers can detect a sign of DSCB malfunction by recognizing the shift of the
zero-point
value.
Noise insensitive digital output incorporated!
The output complies with RS-485 and is insensitive to external noises. Thus, you can use long cables unavailable in conventional load cells and indicators.
Abundant functions incorporated
HI/LO limit comparison & a wide variety of hold functions are included.
Sample, Peak, Bottom, Peak & Bottom, Average can be selected for Hold
function.
Digital low-pass filter and moving average filter can be adjusted by commands.
Connect to PC and PLC directly without dedicated indicator
By connecting to PC, draw waveforms, logging and such operations can be achieved
with dedicated software (for free).
●OK/NOK & stability judgment function
●Easy initial setting
●Waveform drawing
Stability & upper/lower limit comparison status can be checked in one glance
Waveform data can be recorded
●Record
USB dedicated software for DSCB
Display load variation on a load cell in real time via USB.
■ Display setting
●Normal
Data acquisition resumes when “Stop” button is clicked
〇Continuous data recording function
〇USB dedicated software for DSCB
Data acquisition starts when data level passes the specified value in the specified direction.
●History
■ Trigger function
The dedicated software can be run multiply, and it is possible to connect multiple DSCBs with one PC.
* RS-485-USB converter is required to use the USB dedicated software for DSCB.
Recommended product: SI-35USB-L (Made by LINE EYE CO., LTD.)
Specifications
DSCB-1KN, DSCB-2KN, DSCB-5KN
| Model | DSCB-1KN | DSCB-2KN | DSCB-5KN |
|---|---|---|---|
| Rated capacity | 1 kN | 2 kN | 5 kN |
| Safe overload | 500% R.C. | ||
| Non-linearity | 0.1% or less R.O. | ||
| Hysteresis | 0.2% or less R.O. | ||
| Repeatability | 0.1% or less R.O. | ||
| Compensated temperature range |
-10 to +60℃ | ||
| Safe temperature range |
-20 to +70℃ | ||
| Temperature effect on zero | 0.015% R.O./℃ or below | ||
| Temperature effect on span | 0.01% R.O./℃ or below | ||
| Converter resolution |
24 bit | ||
| Deflection at rated | 0.010 mm | 0.012 mm | 0.021 mm |
| Natural frequency | 22 kHz | 22 kHz | 21 kHz |
| Load cell material | Stainless steel | ||
| Weight | 300 g | 300 g | 400 g |
| Power supply voltage |
DC 12 to 24 V±15% (Insulated internally) | ||
| Power consumption | 0.7 W or less | ||
| Digital low-pass filter |
Can be set anywhere between OFF, 0.1 to 999.9 Hz | ||
| Moving average filter |
Can be set anywhere between OFF, 2 to 999 times | ||
| Sampling rate | 4800 times/sec. | ||
| Interface | RS-485 interface (4-wire) | ||
| Operation & setting methods | Display &
configuration by command operation or through dedicated software (Free software) |
||
| Dedicated software function | ・Indicated value
display ・Waveform display ・Setting changes ・Data logging function |
||
| Display digit number |
5 digits (-99999 to +99999 plus decimal point) | ||
| Other functions | ・Digital zero ・OK/NOK judgment (Upper and lower limit comparison: HH, HI, OK, LO, LL) ・Hold function (Sample. Peak, Bottom, Peak & Bottom, Average) ・Calibration date / rated capacity / serial info read-out |
||
| Cable | φ5 6-conductor flexible cable (2 m) Cable end: 7 wires | ||
| Optional accessories | φ5 6-conductor flexible cable (5 m) Cable end: 7 wires | ||
| CE marking certification |
2011/65/EU+(EU)2015/863, 2014/30/EU(EN61326-1) | ||
DSCB-10KN, DSCB-20KN, DSCB-50KN
| Model | DSCB-10KN | DSCB-20KN | DSCB-50KN | |||
|---|---|---|---|---|---|---|
| Rated capacity | 10 kN | 20 kN | 50 kN | |||
| Safe overload | 500% R.C. | |||||
| Non-linearity | 0.1% or less R.O. | |||||
| Hysteresis | 0.2% or less R.O. | |||||
| Repeatability | 0.1% or less R.O. | |||||
| Compensated temperature range |
-10 to +60℃ | |||||
| Safe temperature range |
-20 to +70℃ | |||||
| Temperature effect on zero | 0.015% R.O/℃ or below | |||||
| Temperature effect on span | 0.01% R.O/℃ or below | |||||
| Converter resolution |
24 bit | |||||
| Deflection at rated | 0.025 mm | 0.035 mm | 0.065 mm | |||
| Natural frequency | 24 kHz | 26 kHz | 15 kHz | |||
| Load cell material | Stainless steel | |||||
| Weight | 400 g | 2.0 kg | ||||
| Power supply voltage |
DC 12 to 24 V±15% (Insulated internally) | |||||
| Power consumption | 0.7 W or less | |||||
| Digital low-pass filter |
Can be set anywhere between OFF, 0.1 to 999.9 Hz | |||||
| Moving average filter |
Can be set anywhere between OFF, 2 to 999 times | |||||
| Sampling rate | 4800 times/sec. | |||||
| Interface | RS-485 interface (4-wire) | |||||
| Operation & setting methods | Display & configuration by command operation or
through dedicated software (Free software) |
|||||
| Dedicated software function | ・Indicated value display ・Waveform
display ・Setting changes ・Data logging function |
|||||
| Display digit number |
5 digits (-99999 to +99999 plus decimal point) | |||||
| Other functions | ・Digital zero ・OK/NOK judgment (Upper and lower limit comparison: HH, HI, OK, LO, LL) ・Hold function (Sample. Peak, Bottom, Peak & Bottom, Average) ・Calibration date / rated capacity / serial info read-out |
|||||
| Cable | φ5 6-conductor flexible cable (2 m) Cable end: 7 wires | |||||
| Optional accessories | φ5 6-conductor flexible cable (5 m) Cable end: 7 wires | |||||
| CE marking certification |
2011/65/EU+(EU)2015/863, 2014/30/EU(EN61326-1) | |||||
Example of use
Cable
External dimension
Download
|
Product catalogue(PDF)
|
⇒Download Page | |
|---|---|---|
|
Operation manual(PDF)
|
||
|
External dimension
|
DXF
(ZIP) |
|
|
PDF
|
||
|
Support tools
|
||
|
Software
|
||