F850
Network Type Weighing Indicator
Product outline
F850 is a mid-class loadcell indicator that can be used for wide-ranging applications from weighing scales requiring a high-level sequence such as hopper scales and packing scales to simple applications such as general platform scales.
F850 is a Bessel type low-pass filter that has high-speed A / S conversion and powerful digital processing capabilities of 100 times/sec and a strong attenuation characteristics. SI/FII interface allows easy construction of a network system to communicate with peripherals. F850 is a mid-class loadcell indicator that can be used for wide-ranging applications from weighing scales requiring a high-level sequence such as hopper scales and packing scales to simple applications such as general platform scales. F850X1 is a series controller equipped with a checker function.
Specifications
Analog section|Setting section|I/O section|Display section|General performance|Attachments
Analog section | |
Excitation voltage | 10V DC ±5%, Output current; within 120mA (Up to 4 units at 350Ω are parallel-connectable) |
---|---|
Zero adjustment range | 0 to approx. 2mV/V (digital adjustment) |
Gain adjustment range | 0.3 to 2.0mV/V (digital adjustment) |
Min. input sensitivity | 0.3μV/count |
Accuracy | Non-linearity: within 0.01%/FS (Typ: 0.005%/FS at room temperature) Zero drift: within 0.1μV/°C RTI (Typ: 0.08μV/°C) Gain drift: within 15 ppm/°C (Typ: 5 ppm/°C) Noise: within 0.1μVp-p RTI (0.1 to 10 Hz) |
Analog filter | Bessel low-pass filter (-12dB/oct.), Selectable from 2, 4, 6, 8 Hz |
A/D converter | Speed: 100 times/sec. Resolution: 16bit (binary) |
Min. display resolution | 1/10000 |
Secondary calibration | Calibration can be carried out without an actual load by connecting a resistor to one of the bridges of a loadcell. |
Setting section | |
Setting method | ・ Keyboard operation (keyboard with a key click buzzer) ・ External setting is available by installing RS-232C option |
---|---|
Setting value storage | ・ Initial set values: NOV RAM (Non-volatile RAM) ・ Other set values: C-MOS RAM with backup of a lithium battery (Effective for more than 7 years depending on usage conditions and storage environment) |
Setting value protection | Setting operation can be locked to prevent unauthorized modifications of default values and calibration by malfunction (LOCK) |
I/O section | |
External output signal | Transistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON. |
---|---|
External input signal | ON when shorted to COM terminal by contact (relay, switch) or non-contact (transistor, open collector) |
Interface | SIF: 2-wire type serial interface (standard); Interface to link with Unipulse printer or external display SI2: 2-wire type bi-directional serial interface (standard): Interface to link with peripherals such as printers and display units. 232: RS-232C communication interface (optional): Write (change) / read weight data, various statuses and setting values via commands from host computer |
Display section | |
Display unit | Numerical display with a character height of 17 mm by fluorescent display tube (8-digits) |
---|---|
Weight value display | 5 digits, Sign: Minus sign displayed on most significant digit |
Scale capacity | 5-digit numerical values (up to 99999) |
Character display | 5 x 7 dot matrix display, 24 digits x 2 lines ANK |
Unit display | 5 x 7 dot matrix display, 2-character selectable from t, kg, g, N, lb, none |
Display frequency | Selectable from 25, 13, 6, 3 times/sec. (display only, system speed 100 times/sec.) |
Min. scale division | 1 to 100 selectable |
Decimal point | Selectable from 0. 0.0, 0.00, 0.000 |
Center zero | True zero point (0±1/4 scale) or the center of each value is displayed. |
Message | Menus and guidance for settings are displayed. Operation status of the indicator is displayed when setting is not carried out. |
Status display | HOLD, ZALM, ZT, STAB, TARE, NET, GROSS, CZ, LOCK, NZ, SP1, SP2, SP3, UNDER, GO, OVER, LO, HI |
General performance | |
Power supply voltage | 85 to 110V, 102 to 132V, 170 to 220V, 187 to 242V AC (Please specify when ordering), 50/60Hz |
---|---|
Power consumption | Approx. 15VA |
Operating conditions | Temperature: Working temperature range -10°C to +40°C; Storage temperature range -40 to +80°C Humidity: 85%RH or less (non-condensing) |
External dimensions | 192 (W) x 96 (H) x 154 (D) mm (protruding parts not included), DIN standard size |
Panel cutout dimensions | 186 (W) x 92 (H) mm (+0.5/-0) *Installation panel thickness: 1.6 mm or more |
Weight | Approx. 2.2kg |
Attachments | |
Power supply cable (2m) | 1 |
---|---|
Spare fuse (1A) | 1 |
Mini-driver for terminal block connection | 1 |
Loadcell connector | 1 |
Control signal connector | 1 |
Operation manual | 1 |
Option
Model | Interface |
232 | RS-232C communication interface |
---|
Optional accessories
Model | Description |
CAAC2P-P2 | AC input cord 2m |
---|---|
CAAC3P-CEE7/7-P1.5 | AC input cord (Voltage resistance: 250V) 1.5m |
CN3P-2P | 3P-2P conversion plug for AC input cord |
CA4131 | (6-core) cable with JR connector at one end (cable end is separated) 3m |
CA4230 | JR-PRC conversion relay (6-core) cable 0.3m |
CA4311 | JR-PRC conversion relay (6-core) 4-wire type/6-wire type (for 520A) 1m |
CN22 | 57 series 50p connector for external I/O |
CN35 | D-Sub 25p connector for RS-232C |
LB01-NH | 57 series 24p connector for external input/output |
CN34 | Lithium battery (with NH connector) |
Download
Product catalogue(PDF)
|
F850 Product catalogue Dowmload | |
---|---|---|
Operation manual(PDF)
|
||
External dimention
|
DXF
(ZIP) |
|
PDF
|
||
Support tools
|
||
Software
|
- User registration is required to download operation manuals, external dimentions, support tools and software .
- Acrobat Reader software from Adobe Systems is required to view PDF files.